A

- ABS - Black plastic pipe and fittings. Generally used in waste water and
drainage systems. Introduced in the 1960's, popular for new residential construction
and remodeling.
- AIR CONDITIONING - The process of treating air to simultaneously control
its temperature, humidity, cleanliness and distribution.
- AIR FILTER - A furnace filter installed in line with the cold air return
which filters out dust and debris and prevents its re-entry into the occupied interior.
- AIR RETURN - A furnace duct through which interior cool air returns to the
furnace. This cool air is then circulated through the heat exchanger, warmed, and
distributed through the ducts.
- AIR POCKET/BLISTER - A bubble in the roofing surface formed by water vapor
expanding between the layers of a built-up roofing membrane. This condition can
reduce the useful life of the roofing surface and is conducive to moisture penetration
and subsequent leakage.
- ALUMINUM WIRING - A type of conductor used to carry current. The U.S. Consumer
Product Safety Commission has determined that aluminum wiring used in 120 Volt light
and outlet circuits can be hazardous and a cause of fire. A failure can occur because
aluminum wire behaves differently than copper wire when current travels through
the conductor. An aluminum wire will expand and contract more than a copper wire.
The expansion and contraction can result in loose connections. The loose connections
can oxidize. The loose, oxidized connections can spark or overheat when current
flows to the connection. The spark or overheating can cause a fire. This potential
problem has nothing to do with the wires in the walls, floors or ceilings. This
problem occurs only at the connections. It is possible to control and repair this
condition. Typically, aluminum is no longer used in the individual branch lighting
and receptacle circuits. It is still commonly used and approved to bring power to
a structure and to energize the distribution panels as well as power the individual
appliance circuits. Aluminum wire should only be connected to listed and rated devices
(breakers, outlets, switches, etc.). Additionally, these devices should have an
anti-oxidant installed to cover the connections. As a preventive measure, each accessible
aluminum connection should be periodically checked by a licensed electrician to
insure that it is securely fastened. If aluminum wiring has been installed in the
individual lights, switches and receptacles, we recommend repair with crimp connectors.
This repair consists of attaching a short length of copper wire onto the existing
aluminum wire with a specially designed metal sleeve and an air-powered crimping
tool. This makes a permanent connection that is, in effect, a cold weld. An insulating
sleeve is heat shrunk around the crimp connection to complete the repair. This is
in accordance with the recommendation of the U.S. Consumer Product Safety Commission.
- AMBIENT TEMPERATURE LESS THAN 65 DEGREES - The temperature of the air surrounding
air conditioning equipment should be at least 65 degrees for 12 hours before the
equipment is operated. Operating the compressor in cold temperatures can severely
damage the compressor.
- AMP - Short for Amperes. The rate of flow of electricity through wire.
- ANCHOR BOLT - A bolt used to secure a wooden sill plate to a concrete or
masonry floor or wall. The purpose of the bolt is to limit the ability of the framing
to move independent of the foundation in the event of seismic activity.
- ANGLE STOP - A shut-off valve arranged in a 90-degree configuration. It is
used to shut off the flow of water to a fixture. A double angle stop is an angle
stop that controls both the hot water to the sink faucet and to the dishwasher.
As a preventive measure, we recommend the installation of a separate fixture shut-off
valve for the dishwasher. This will allow for the uninterrupted use of the kitchen
sink in the event of necessary repair or removal of the dishwasher.
- ANTI-SIPHON VALVE - A device installed on irrigation piping designed to prevent
the drawing of contaminated ground water into the domestic water supply system.
- ASBESTOS - Asbestos is a naturally occurring mineral fiber extensively used
in construction. Nearly every building contains asbestos in some form. It may be
found in vinyl flooring, patching compounds and textured paints, sprayed acoustic
ceilings, acoustic ceiling tiles, stove insulation, furnace insulation, pipe insulation,
wall and ceiling insulation, roofing, shingles and siding as well as appliances.
Exposure to asbestos can be a serious threat to one's health. There are a number
of choices available for dealing with asbestos. They include leaving it alone, encapsulation
and abatement. Removal of this material is a specialized procedure and should be
attempted only by a qualified and licensed expert. Information regarding identification
of asbestos, its hazards and safe removal may be obtained from the U.S. Consumer
Product Safety Commission, Environmental Protection Agency and other governmental
agencies.
- AUTOMATIC SAFETY CONTROLS - Devices designed and installed to protect systems
and components from excessively high or low pressures and/or temperatures, excessive
electrical current, loss of water, loss of ignition. fuel leaks, fire, freezing,
or other unsafe conditions.
- AUTOMATIC GARAGE DOOR OPERATOR DOES NOT REVERSE
- The garage door was tested and did not automatically reverse. This indicates that
the door opener does not have an auto-reverse mechanism, it is broken or it needs
adjustment. We recommend that the opener be modified, replaced or adjusted as necessary.

B

- BALLOON FRAMING - A type of framing system where the studs extend from the
sill to the roof.
- BLOWER - A fan in a furnace or air conditioning unit which blows air through
ducts.
- BLOWER BEARINGS WORN - The forced-air furnace fan bearings are worn. The
fan bearings should be lubricated if possible. Damaged bearings may need to be replaced.
It is possible that the fan itself may need replacement.
- BOILER - A heating device which heats hot water or creates steam for circulation
in heating pipes, radiators. Baseboards or convectors.
- BOILER LEAKS - Boiler leaks must be repaired or there may be a loss of heat
and the boiler may be damaged beyond repair.
- BRASS GAS CONNECTOR - Brass is made of zinc and copper. The sulfur in the
natural gas reacts with the copper and can cause the piping to become brittle, deteriorate
and leak. We recommend that this tubing be removed and replaced with an approved
gas supply connector.
- BREAKER BRIDGE MISSING - A 240 volt double pole breaker installed without
a bridge between the two pole handles. We recommend that this breaker be bridged.
This will insure that all of the power is shut off to this circuit if the overcurrent
protection device is tripped.
- BRIDGING - Short, structural members criss-crossed between floor or ceiling
joists to provide reinforcement and distribution of stress.
- BRITTLE SURFACE - The roofing surface is brittle and subject to breakage.
This condition is an indication of age and suggests that the roofing surface is
near the end of its useful life.
- BROKEN/FRAYED SASH CORDS - The cords along each side of a double hung window
which are attached to counter weights in the wall. The sash cords hold the window
open. The window will not stay open by itself if they are broken. Frayed sash cords
are likely to break. These sash cords should be replaced to ensure that the windows
remain operable.
- BTU - British Thermal Unit, a unit of measure of heat. One BTU is the quantity
of heat needed to raise the temperature of one pound of water one Fahrenheit degree.
- BURIED FUEL OIL TANK
- We found evidence to suggest the presence of a buried fuel oil tank. Removal of
such tanks and soil testing may be required. A determination as to the presence
and condition of buried tanks as well as possible soil contamination is beyond the
scope of our inspection.

C

- CAULK/SEAL GAPS - Gaps in the exterior of the building around the doors,
windows and plumbing and electrical entry points. All gaps should be caulked and
sealed to prevent heat loss, air infiltration and moisture entry.
- CELLULOSE DEBRIS - Scrap-wood found in the substructure soil area. This debris
can result in the infestation and infection of wood-destroying pests and/or organisms.
It should be removed.
- CIRCUIT - The path of electricity away from and back to its source.
- CIRCUIT BREAKER - An overcurrent protection device which automatically opens
an electrical circuit when too much current flows through the conductor.
- COMPRESSOR - A pump which forces refrigerant through an air conditioning
system.
- COMPRESSOR SHORT CYCLES - A suspected compressor defect. A qualified air
conditioning contractor should be contacted to evaluate the air-conditioning system
and determine the corrective measures needed.
- CONDENSATION - In a building: Beads or drops of water that accumulate on
the inside of the exterior covering of a building when warm, moisture-laden air
from the interior reaches a point where the temperature no longer permits the air
to sustain the moisture it holds. The use of louvers or attic ventilators will reduce
moisture condensation in attics. A vapor barrier under the gypsum lath or dry wall
on exposed walls will reduce condensation in them. A plastic vapor barrier over
damp subarea soil will help create a dry air space between the damp soil and the
floor framing, thereby helping to limit the amount of moisture that is able to rise
into the framing, and reducing the possibility of future damage and deterioration.
- CONDUCTOR - An electrical wire capable of carrying current.
- CONDUIT - A hollow pipe (metal or plastic) casing through which electric
wires run.
- CONVECTION - The transfer of heat by the motion of the heated matter.
- COPPER GAS CONNECTOR - Sulfur in natural gas reacts with copper and can cause
the connector to deteriorate and leak. We recommend that copper tubing be removed
and be replaced with an approved gas supply connector.
- CRACKED HEAT EXCHANGER - A fracture in the walls of the furnace combustion
chamber. The heat exchanger separates the flame and combustion products from the
air chamber. A crack in the heat exchanger may allow the products of combustion
to enter the occupied interior. One of the products of combustion is carbon monoxide.
In addition to carbon monoxide, natural gas combustion produces formaldehyde gas.
Depending on the authority and study published, acceptable levels of carbon monoxide
and formaldehyde gas in an indoor environment vary greatly. There are a number of
testing methods practiced to determine if a heat exchanger is cracked. They can
be reduced to a two step process. First, a visual inspection with a flashlight can
reveal a crack, which can be confirmed by feel to insure that it is not simply discoloration
or distortion. Another first step is flame observation. The furnace flame is observed
before and after the circulating air comes on. Floating flames, flame rollout and
flame distortion can indicate a failure of the heat exchanger. The second step is
tracer gas. A tracer gas is injected into the combustion chamber and a calibrated
gas detector is used to check for the presence of the tracer gas on the air side
of the heat exchanger. Neither visual inspection nor flame distortion should be
used to confirm the other. Although a tracer gas test would be necessary to verify
observations made visually or by flame and determine actual levels of carbon monoxide
or formaldehyde gas, our experience has shown that identification of a crack by
visual inspection is sufficient to recommend that the furnace be repaired or replaced.
Although it may be possible to repair or replace the heat exchanger, it is usually
not considered cost effective, and parts may be difficult or impossible to find.
The most common course of action is to replace the furnace.
- CRACKED MASTIC - Cracks in the roof cement coating used to seal the roof
connections and penetrations. This creates a condition conducive to moisture penetration
and subsequent leakage. We recommend that these areas be repaired as necessary to
prevent leakage.
- CRACKED/DETERIORATED MORTAR - Cracks and deterioration in the mortar used
to seal the tile roof joints. This creates a condition conducive to moisture penetration
and subsequent leakage. Cracked and deteriorated tile mortar should be replaced.
- CRACKS IN INTERIOR WALLS/CEILINGS - Hairline cracking in the interior walls
and ceilings, as well as minor sloping and sagging of floors and door casings, should
be expected as a result of ordinary settlement and expansion of the foundation system,
structural framing, and soil. These conditions do not, in our opinion, represent
a failure of the framing system. We are not registered engineers. Additional information
concerning settlement of the structure and building, site, would have to be obtained
by retaining a qualified registered engineer.
- CREOSOTE - One of the by-products given off when burning wood. Creosote condenses
on the walls inside the fireplace chimney. It is highly combustible and, if sufficiently
heated, can ignite and start a flue fire. Fireplaces and chimneys should be cleaned
annually or when one eighth to one quarter of an inch of creosote accumulates.
- CURRENT
- A flow of electric charge.

D

- DAMAGED CONDUCTOR INSULATION - We found damaged service conductor insulation.
We recommend that all exposed conductors be repaired or replaced as necessary.
- DAMAGED RAFTERS - Damage to any of the parallel beams that support a roof.
All damaged rafters should be reinforced or replaced. Sometimes the rafters extend
beyond the exterior walls. These rafter tails are subject to moisture damage. They
must be maintained or damage will result.
- DAMAGED SHEATHING - Damage to the material used to cover the outside wall
of a frame house or a timber roof. We recommend that all damaged material be replaced.
- DAMAGED WINDOW FRAMES - Damaged windows are often a result of deferred maintenance.
We recommend that all damaged window,, he repaired or replaced as necessary.
- DEAD-FRONT - Switches, circuit breakers, switchboards, control panels and
panel board fronts must be covered so that no current-carrying parts are exposed.
This cover is called a Dead-Front.
- DEBRIS ON ROOF OR IN GUTTERS - Gutters filled with debris should be cleaned
to ensure proper drainage. Roofing surfaces covered with debris should be cleaned
not only to ensure proper drainage but also to prevent premature deterioration of
the roof surface.
- DECK MOISTURE MEMBRANE FAILED - See moisture membrane.
- DECK RAILING UPGRADE - We recommend that all decks and landings 30 inches
or more above the ground have a railing. The railing should be at least 36 inches
high and the spacing between the railing pieces should be no more than four inches.
- DOUBLED-UP BRANCH CIRCUIT - Two circuits controlled by one overcurrent protection
device. This wiring method increases the possibility of tripping the overcurrent
protection device. Each circuit should be separately fused with an overcurrent protection
device of appropriate amperage.
- DOWNSPOUT/GUTTER LEAKS - A leaking gutter or downspout can allow water to
penetrate a sidewall and enter the occupied interior through a foundation wall or
slab. Deteriorated gutters and downspouts should be repaired or replaced as necessary.
- DRIP LOOP - A loop in each of the overhead electrical service entrance conductors
designed to prevent the passage of moisture into the weatherhead service raceway
or equipment.
- DUCTS
- Metal piping used for distributing warm or cool air.

E

- EARTH-WOOD CONTACT - Wood in contact with dirt. This condition is conducive
to the infestation and infection of wood-destroying pests and/or organisms. We recommend
that all earth-wood contacts be broken and any damaged or deteriorated material
be replaced.
- EAVE - The part of the roof which extends beyond the sidewall.
- EFFLORESCENCE - A deposit of soluble salts, usually white, on the surface
of concrete and masonry walls due to evaporation of water.
- ELECTROMAGNETIC RADIATION - Electromagnetic fields are produced by alternating
current in electric wires. There are two components: an electric charge and a magnetic
force, resulting in electromagnetic radiation. High current power lines are a source
of electromagnetic fields. Studies have suggested a possible increase in leukemia,
cancer and miscarriages from exposure to electromagnetic radiation. Studies are
currently in progress to help quantify the risks. More information can be obtained
from the local utility company, U. S. Department of Energy (202) 586-5000 and the
U. S. Environmental Protection Agency (202)260-7676.
- EXPOSED AND ACCESSIBLE - Our inspections are limited to a visual review of
those areas of the premises which are exposed to view. Any area which is not exposed
to view, or is otherwise inaccessible because of soil, walls, floors, ceilings,
carpets, furnishings, storage, or any other things, and is concealed, is not included
in our inspection. Our inspection does not include any destructive testing or dismantling
of equipment, systems, or surfaces. With access and an opportunity for examination,
reportable conditions maybe discovered. If inspection of inaccessible areas is desired,
this will be performed upon arrangement at an additional cost to the interested
parties at such time as access can be provided.
- EXPOSED WIRING - Wiring or connections not properly covered and protected.
We recommend that all of these connections be repaired and be properly protected.
- EXPOSED ROOF FASTENERS - An indication of significant roofing surface wear
or poor installation. This creates a condition conducive to moisture penetration
and subsequent leakage into the occupied interior. All exposed fasteners should
be covered.
- EVAPORATION COILS
- The part of the air conditioning system where the refrigerant returns; to gaseous
form. Frequently located in the furnace plenum.

F

- FAILED - Something that no longer functions as designed or intended.
- FASCIA - A flat, vertical board enclosing the overhang, under the eave that
runs along the roof edge.
- FELT EXPOSED/WORN - An indication of significant roofing surface wear. Prolonged
exposure to the sun can damage the felt. Damaged felt can result in moisture penetration
and subsequent leakage into the occupied interior. The deteriorated roofing surface
should be repaired, all damaged felt replaced, and exposed felt covered.
- FIRE-RESISTIVE BARRIER - A fire-resistive separation barrier. Fire-resistive
walls may not have been required at the time of construction. Present building code
requires a one-hour fire-resistive barrier between the garage and the occupied interior.
The purpose of this barrier is to prevent the spread of fire from the garage into
the living areas. Flammable liquids are often stored in the garage. The risk of
a fire starting in the garage is significant enough to warrant recommending that
a one-hour fire-resistive barrier be installed.
- FLASHING - Material used at connections and penetrations in a roof or wall
to prevent leakage.
- FLASHING DEFECTIVE - Flashing installed improperly which creates a condition
conducive to moisture penetration. The connections and penetrations must be repaired
to prevent leakage.
- FLASHING INADEQUATE -Insufficient flashing. This condition often leads to
leakage. We recommend that all to door, window, deck and roof connections and penetrations
be properly flashed to prevent moisture penetration.
- FLATWORK - A concrete or asphalt surface such as a sidewalk, driveway or
patio. Any cracks should be patched and any holes or gaps filled. The flatwork should
be examined periodically for signs of failure or further deterioration and repairs
made if necessary. Replacement may be necessary at some point in time.
- FLEXIBLE GAS CONNECTOR - Older installations of gas-fired appliances often
use rigid gas piping. This piping is subject to damage in the event of support movement.
We recommend that all gas-fired appliances be equipped with flexible gas connectors
or swing joints as appropriate. This should help reduce damage in the event of an
earthquake.
- FORCED-AIR SYSTEM - A heating system in which air is heated in a furnace
and distributed through a structure aided by a blower.
- FORMALDEHYDE - Colorless, pungent gas used as raw material in manufacture
of particle board, decorative paneling, fiberboard, wafer board, carpeting, permanent-press
fabrics and foam insulation. Heat & humidity increase the level of emission, however,
the rate diminishes as materials age. The U.S. Environmental Protection Agency classifies
formaldehyde as a possible carcinogen. Formaldehyde can also irritate the eyes,
nose and throat, and cause headaches and dizziness. Formaldehyde levels can be reduced
by increasing ventilation, reducing temperature and humidity and reducing the number
of new pressed-wood products in a home. Removal of wood paneling or subflooring
is sometimes necessary. More information is available from the U. S. Environmental
Protection Agency (202)260-2080.
- FORM-WOOD - Wood used in the forming of a concrete foundation or retaining
wall, typically removed after the concrete has set. If it is left in place, it can
lead to the infestation of wood-destroying pests. We recommend that all form wood
be removed.
- FOUNDATION - Construction below or partly below grade, which provides support
for exterior walls or other structural pans of the building.
- FOUNDATION OUTDATED - An old foundation that is weak and subject to failure
because of its age, condition and design. A brick foundation would be an example.
Although an outdated foundation may not have failed, it is likely to be severely
damaged in the event of seismic activity and is more susceptible to moisture damage.
Replacement may not be necessary now, but may be necessary at some point in the
future. Unfortunately, it is difficult to determine when to act. Obviously, if one
waits until it fails, one waited too long.
- FROZEN FIXTURE SHUT-OFF VALVES. - Plumbing shut-off valves that no longer
turn. This occurs when the valves are seldom operated. An inoperable valve prevents
the water from being turned off if it is necessary to repair the fixture. We recommend
that they be repaired and be made operable again.
- FUNCTIONAL DRAINAGE - A plumbing drain is functional when the fixture empties
in a reasonable amount of time, and does not overflow when another fixture is drained
simultaneously.
- FUNCTIONAL FLOW - A reasonable flow at the highest fixture in a dwelling
when another fixture is operated simultaneously.
- FUSE - An overcurrent protection device with a circuit opening fusible member
directly heated and destroyed by the passage of too much current through it.
- FUSED NEUTRAL
- Where an electrical neutral wire is fused. If the fuse on the neutral wire blows,
the circuit will be open, and the fixtures and/or appliances on this circuit will
not function. However, power will still be present through the circuit, right up
to the outlet. This creates a shock hazard. We recommend that this condition be
corrected.

G

- GABLE ROOF - A roof with two pitches, designed to provide more space on the
upper floors.
- GALVANIZED PIPE - Steel pipe with a protective zinc coating. Used for supply
of domestic water and waste and vent piping.
- GARAGE DOOR SPRINGS - Prior to 1976, the counter balance springs used for
tilt-up garage doors were not provided with a safety device to control spring breakage.
Without the benefit of a safety device, it is possible that pieces of the spring
may fly across the garage upon accidental breakage. We recommend that the garage
door be springs be upgraded.
- GATE VALVE - A shut-off valve using a rising disc (gate) to control liquid
flow.
- GFCI - Ground Fault Circuit Interrupter: a safety device which monitors the
difference between current flowing through the hot and neutral wires of a receptacle.
If there is an imbalance of current greater than five milliamps, the current will
be cutoff in less than a second. GFCI protection is recommend in the garage, outdoor
and bathroom receptacles. We also recommend that all pool and spa equipment have
GFCI protection. We further recommend that all kitchen receptacles within six feet
of a sink be equipped with GFCI devices. This will reduce shock and short hazards.
- GRADE - The ground level around a structure. When the ground is less than
six inches below the top of the foundation, it is considered a marginal grade. A
faulty or marginal grade can lead to moisture damage and/or pest control problems.
If damage Is discovered, we recommend that the height of the foundation be raised
to a minimum of six inches above the ground and that all damaged material be replaced.
If no damage is present, we recommend that this area he periodically reviewed by
a qualified individual for signs of drainage. Repairs should be made if necessary.
- GROUND CONDUCTOR SPLICES AND LOOSE CONNECTIONS - The system ground is ineffective
because of splices and loose connections in the grounding conductor. We recommend
that the grounding conductor be repaired or replaced as necessary.
- GROUND RECEPTACLES - A random sampling of individual receptacles found these
to be operable but some are not grounded. We recommend that all kitchen, bathroom,
outdoor, garage and interior three-pronged receptacles be properly grounded in accordance
with current building practice.
- GROUNDED - A conducting connection, whether intentional or accidental, between
an electrical circuit or equipment and the earth, or to some conducting body that
serves in the place of the earth.
- GROUND WATER CONTAMINATION - Ground water can be contaminated from leaking
underground storage tanks, illegal dumping, poorly contained landfills or hazardous
waste spills. Contaminated ground water can be hazardous to one's health if it used
for gardening or irrigation. Qualified individuals would have to be retained for
evaluation and a determination of what corrective steps may be necessary.
- GUSSET
- A strap made of metal or wood attached at the connection of roof trusses or rafters
or foundation area beams and posts. Gussets will help limit the framing's ability
to laterally rack in the event of high winds.

H

- HEAT EXCHANGER - A device by which heat is exchanged from one heat-carrying
medium to another without direct contact between the two media.
- HIP ROOF
- A roof with no gables; usually has inclined planes on all four sides of the building.

I

- INACCESSIBLE- Any area which is not exposed to view or is concealed because
of soil, walls, floors, ceilings, carpets, furnishings, storage, or any other things
is inaccessible. Inaccessible areas are not included in this inspection. Reportable
conditions may be present in inaccessible areas. If review of inaccessible areas
is desired, this will be performed upon arrangement at an additional cost to the
interested parties at such time as access can be provided.
- INADEQUATE FOUNDATION CLEARANCE - Foundation area clearance between the soil
and the wooden framing which is less than eighteen inches. Insufficient clearance
does not allow access for inspection or maintenance and creates a condition conducive
to moisture damage and decay of wooden members. We recommend that a minimum of eighteen
inches of clearance be provided between the soil and the framing. Any damaged wooden
material found in the course of this work should be replaced.
- INADEQUATE CLEARANCE TO COMBUSTIBLES - Gas-fired appliance vents must be
far enough away from combustible surfaces to prevent the heat that these vents carry
from causing a fire. Single wall vents should be at least six inches away from combustible
surfaces and double wall vents should be at least one inch away.
- INADEQUATE COMBUSTION AIR - The oxygen-carrying air which fuel burners need
to operate safely. It Is normally supplied through venting ducts or openings in
walls or doors. We recommend that additional venting be installed.
- INADEQUATE FOUNDATION DRAINAGE - Continuous foundation area moisture accumulation
causes damage and/or deterioration to the foundation and/or framing. We recommend
that the drainage be upgraded as necessary to collect the surface and subsurface
moisture approaching the foundation and route it to some central drainage collection
point. All damaged foundation and framing should be repaired or replaced as necessary.
- INADEQUATE ROOF DRAINAGE - Significant roof ponding can indicate inadequate
drainage. Standing water can result in leakage. We recommend that the drainage be
upgraded as necessary to properly collect and divert water off of the roof.
- INSUFFICIENT ROOF SLOPE - A shingle type roofing surface applied over framing
whose pitch is less than three inches in twelve inches. This means that for every
twelve horizontal inches the roof fails to rise at least three inches. This roofing
surface is subject to leakage because of poor drainage. We recommend that the roof
be periodically checked for signs of moisture penetration and patched and sealed
as necessary to prevent leakage and subsequent damage. At such time as replacement
of this roofing surface is made, we recommend the installation of a conventional
built-up or single ply roofing membrane.
- INSULATION INSTALLED BACKWARDS
-Insulation installed with the vapor barrier pointed away from the living space.
This can cause a buildup of moisture and subsequent damage. We recommend that this
insulation be repaired and installed with the vapor barrier pointed toward the heated
side of the building. Any damaged material found in the course of this work should
be replaced.

J

- JOISTS
- Parallel, horizontal boards laid edgewise from wall to wall to support the boards
of a floor or ceiling.

L

- LAMPCORD WIRING - Unapproved extension cord wiring running along the outside
of finished walls, floors or ceilings (sometimes referred to as zipcord wiring).
It is easy to overload the wire and the wire is subject to physical damage. All
lampcord wiring should be removed. Additional convenience outlets can be installed
if desired.
- LEAD CONTAMINATION - Lead can be present outside a structure in the soil
as a result of automobile exhaust and exterior lead-based paint. Lead paint may
have been used on the outside of the building and have found its way into the soil.
Proximity to busy roadways can result in automobile emissions elevating lead levels.
- LEAD PAINT - Lead-based paint is a hazard when paint chips and particles
and dust are ingested by children. Lead accumulates in the blood, soft tissues and
bones, leading to damage to the kidneys, brain and central and peripheral nervous
systems. Children are more susceptible to the toxic effects of lead paint because
lead is more easily absorbed into growing bodies. Precautionary measures include
removing lead from children's environment, mopping floors and window sills to remove
lead dust and washing hands before eating. Abatement contractors must use extensive
precautions to prevent contamination from lead dust.
- LEDGER FLASHING MISSING - The ledger is a piece of horizontal lumber, usually
a 2 x 8 or 2 x 10 bolted or nailed to the exterior of a building. Joists are attached
to the ledger and the finished decking or stair landing material is secured to the
joists. Water seeping behind the ledger can cause damage to the siding and franuing.
Ideally, the ledger should be flashed at the top edge to prevent moisture penetration
behind the ledger and around the ledger fasteners. A secondary method of dealing
with this condition is to keep the top edge of the ledger caulked and sealed as
well as applying caulking at the ledger fasteners. When the ledger is replaced it
should be properly flashed and sealed.
- LOOSE/MISSING/WORN SHAKES OR SHINGLES
- A condition conducive to moisture penetration and subsequent leakage into the
attic and/or occupied interior. We recommend repair or replacement as necessary
to prevent leakage.

M

- MAIN DISCONNECT - A device by which the electrical system can be disconnected
from its source of supply. Six or more branch circuits require a main disconnect
device.
- MASTIC - Asphalt material used to seal around roof connections and penetrations.
- MINIMAL SURFACE PREPARATION - Premature weathering of painted and/or stained
exterior surface due to minimal surface preparation. Prior to the next application
of paint and/or stain, we recommend the exterior be properly prepared.
- MOISTURE BARRIER - Treated paper or metal which retards or bars water vapor.
It is used to keep moisture from passing into walls and floors.
- MOISTURE MEMBRANE HAS FAILED - The moisture membrane has failed when water
has penetrated through the moisture barrier. There may be damaged framing below.
All damaged material must be replaced or the damage may spread. Moisture must be
prevented from penetrating the framing or additional damage will occur. Our primary
recommendation is to install a new moisture membrane. This will stop any further
leakage and subsequent damage. It may be possible to seal the surface above, thereby,
hopefully stopping further water penetration. However, there is no guarantee that
sealing the surface will work and this repair will require frequent maintenance.
- MOSS BUILDUP - Moss retains moisture and can damage the roofing surface.
We recommend that the moss be removed.
- MULTIPLE LAYERS - Multiple roofing surfaces add extra weight to the roof
framing. Too much weight can crack framing members. Most local building departments
limit the number of roofing surfaces to three. Some, however, limit it to two. Another
problem that can occur with multiple roofing surfaces is the inability to effectively
seal the roof connections and penetrations, a critical component of the roofing
system. When multiple surfaces are present, the usual way to seal the connections
and penetrations is with a plastic roof cement coating. Unfortunately the plastic
roof cement coating does not last as long as the roofing surface and requires more
frequent maintenance than metal flashing. At such time as replacement of the roofing
surface is made, we recommend that all of the existing roofing surfaces be removed,
the framing resheathed as necessary and all roof connections and penetrations reflashed
before the new surface is installed. This will help reduce the weight on the framing
and the possibility of cracking as well as prolong the useful life of the new roof.
- MULTI-WIRE BRANCH CIRCUIT
- An electrical circuit consisting of two or more ungrounded conductors having a
potential difference between them and a grounded conductor having, equal potential
difference between it and each ungrounded conductor. This type of circuit is commonly
used to energize the dishwasher and garbage disposal outlet located in the sink
base cabinet. A common problem arises when both hot conductors of the circuit are
connected to the same pole or leg of the distribution panel. If both the dishwasher
and disposal are operated at the same time, the breaker protecting the circuit will
not trip. This is a potential hazard and the circuit should be repaired.

N

- NEGATIVE GRADING - Grading which is sloped toward the structure. Low spots
and negative grading will increase the chances of water penetration through the
foundation and subsequent pooling or puddling in the basement, garage and/or subarea.
We recommend that the site be regraded as necessary to make sure that surface water
runs away from the structure. Any damaged material found in the course of this work
should be replaced.
- NO SAFETY GLASS - A random sampling of exterior doors and windows and review
of individual shower doors, it revealed some areas which lack safety glass. This
is not uncommon in older buildings as safety glass may not have been required at
the time of installation. Doors and windows not equipped with safety glass are hazardous
if broken. Present industry standards require safety glass to minimize this hazard.
- NO SIGN OF SIGNIFICANT NON-PERFORMANCE - Capable of being used.
- NOT PRESENT - Not installed.
- NO UNDERLAYMENT
- A tile roof installed directly over the sheathing without an underlayment. An
underlayment provides a moisture barrier between the tile and the attic. The manufacturer's
specifications may permit this method of installation; however, it is our opinion
that without an underlayment, this roof is subject to premature leakage. We recommend
that the tile surface and the connections and penetrations be periodically examined
by a qualified and licensed roofing contractor for signs of damage and leakage and
repairs be made if necessary.

O

- OUTLET (ELECTRICAL) - A switch, light or receptacle.
- OVERFUSED
- A fuse or breaker too large for the rated capacity of the circuit. This allows
too much current to flow through the conductor (wire) before the overcurrent protection
device blows or trips. This is hazardous. The rated capacity of the circuit may
not have been exceeded yet. However, increased demand on the circuit may result
in the conductor overheating which can cause a fire. We recommend that all overfused
branch circuits be repaired and equipped with overcurrent protection devices of
appropriate amperage.

P

- PAINT/STAIN WEATHERED - Portions of the exterior are weathered, exposed and
subject to damage. We recommend that all exposed areas be sealed to provide protection
against inclement weather. Prior to the next application of paint and/or stain,
we recommend that the exterior be properly prepared.
- PANEL RUSTED - All rusted panels should be primed and sealed to prevent further
deterioration.
- PARAPET WALL - The part of the sidewall of a structure which extends above
the roof line.
- PARGING - A coat of cement over block foundation walls, or a coat of plaster
over stone or brick walls.
- PENETRATIONS - Any projection through a roofing surface necessitating flashing,
such as plumbing vents and skylights.
- PLATFORM FRAMING -A type of framing where each story is built on a platform
and the studs run the height of each story.
- PLENUM - A large duct or air chamber in which the hot air from the furnace
is distributed to the ducting and through the ducts to the registers.
- POINT-UP MORTAR JOINTS - To fill and finish the joints between bricks with
cement or mortar. Often called Tuck Pointing. We always recommend that this work
be done by experienced professionals.
- POLARITY REVERSED - An electrical receptacle which has been wired with the
hot and neutral wires reversed. Reversed polarity can compromise the grounding of
an appliance and cause some electrical equipment to operate improperly. We recommend
that the polarity be corrected.
- PULL CHAIN LIGHT NEAR WATER - Pull chain lights in rooms with running water
are dangerous. Their proximity to running water creates a shock hazard. We recommend
that these lights be equipped with approved and grounded switches.
- PVC
- Rigid white plastic pipe and fittings used for supply of domestic water and yard
sprinkler systems and in interior drain, waste and vent systems. Introduced in the
1960's.

R

- RADON - Radon is a colorless, odorless gas that occurs as part of natural
decay of uranium. Radon is present to some extent in all soils and groundwater and
its levels vary within geographic areas. Radon is classified by the U.S. Environmental
Protection Agency as a known carcinogen. There are no immediate symptoms resulting
from exposure to radon. Most radon enters the home through cracks and openings in
concrete slabs, crawlspaces, sumps and the tiny pores in hollow-wall concrete blocks
from the soil underneath. Sometimes radon enters homes through well-water. The level
of radon can be measured and mitigation measures taken if necessary. Contact the
Colorado Department of Health Radon Program for a list of radon testing laboratories
and mitigation contractors who meet federal requirements. Additional information
may be obtained from the U.S. Environmental Protection Agency.
- RAFTER - One of a series of inclined structural members which support the
roof, running from the exterior wall to the ridge board.
- RAISED/CURLED SEAMS - see SURFACE GRANULATION FAILURE.
- RANDOM SAMPLING - For multiple identical components such as windows, doors,
electrical outlets or heating registers. One per room is chosen at random.
- RECEPTACLE - An electrical device to receive the prongs of a plug and which
is connected to an electric circuit.
- REGISTER - A fixture installed at the end of a duct which controls and directs
the flow of air into a room.
- RELOCATE LIGHT SWITCH - The bathroom light switch is located in the shower
receiving wall. This is hazardous. We recommend that the light switch be moved to
a safe location.
- REPAIR RECOMMENDED -An item which no longer functions as designed or intended
and should be repaired or replaced as necessary.
- RIDGE BOARD - The horizontal structural member at the top of a roof where
the rafters meet.
- ROOF PITCH - The degree of slope of a roof.
- ROOMS WITHOUT HEAT - Some areas of the structure are without heat. Individual
need may necessitate upgrading of this heating system.
- ROTATION - A significant number of older foundations were constructed without
steel reinforcement and with shallow footings. The weight of the structure was placed
on the outer edge of the foundation wall. This design commonly results in some leaning
of the foundation. Poor drainage is often times the catalyst for rotation. Rotation
does not necessarily mean that the foundation has failed. It does weaken the foundation
and it is more vulnerable to excessive moisture conditions and seismic activity.
The foundation can be repaired. However, if left unattended, this condition will
worsen and may eventually result in a failure of the foundation which would require
replacement.
- ROUTE DOWNSPOUTS - All downspouts that do not terminate within drain lines
should be routed sufficiently away from the foundation to prevent puddling and pooling
and subsequent seepage through the foundation and into the basement, garage and/or
subarea.
- ROUTE TEMPERATURE AND PRESSURE RELIEF VALVE - We recommend that the water
heater temperature and pressure relief valve be routed to an approved drain or safely
to the exterior. This will help limit damage in the event of a release of the relief
valve.
- RUNNING SPLICE - An electrical connection made without proper protection.
We recommend that all of these connections be repaired and be mechanically protected.
- RVAC UNIT
- A single unit which supplies heating, venting and air conditioning.

S

- S-TRAP - A sink drain line configuration in which the piping beyond the trap
runs vertically instead of horizontally. This can cause the water in the trap to
be siphoned out, allowing sewer gas to enter the occupied interior. We recommend
that the pipe after the trap be repaired so that it runs horizontally with a slight
downward slope until it joins the main drain and vent piping, or that an approved
mechanical vent be installed.
- SCREEN DOWNSPOUT OPENINGS - All downspout openings should be screened to
help prevent debris blockages and subsequent drainage failures within these lines
or the drain lines into which they terminate.
- SETTLEMENT - Settlement is that instance in which some portion of the foundation
drops below the original "as built" grade. This occurs as a result of a loss of
bearing compaction of fill, erosion of supporting soil and/or dehydration (shrinkage
of supporting soil)
- SHAKES - Handsplit shingles.
- SHEATHING - The material used to cover the outside wall of a frame house
or timber roof.
- SHOWER RECEIVING WALL - The walls surrounding a shower which, because of
their orientation in relation to the shower head, are likely to be wetted by the
direct or indirect spray from that shower head.
- SIDING EMBEDDED IN THE GRADE - Exterior siding embedded in the exterior grade
is subject to moisture damage and pest control problems. We recommend that this
condition be corrected. Any damaged material found in the Course of this work should
be replaced.
- SIGN OF SIGNIFICANT NON-PERFORMANCE REQUIRING IMMEDIATE CORRECTION - A system
or component which no longer functions as designed and intended. All Such items
require immediate correction.
- SILL PLATE - Framing lumber placed on and around the foundation to support
exterior wall studs and outer floor joists.
- SILT MARKS - When a subarea gets wet enough for water to pond, it can leave
a sediment deposit on the foundation walls and foundation area support piers.
- SOFFIT - The underside of an overhang of structural members, such as staircases,
beams and eaves.
- SOIL CONTAMINATION - Soil can be contaminated from leaking underground storage
tanks, illegal dumping, poorly contained landfills or hazardous waste spills. Contaminated
soil can be a health hazard, especially for children. Qualified individuals would
have to be retained for evaluation and a determination of what corrective steps
may be necessary.
- SOIL PIPE - Pipe carrying organic waste.
- SPALLING - Breaking off of the surface of brick or concrete.
- SPLITS/CRACKS/TEARS - A roofing surface condition conducive to moisture penetration
and subsequent leakage. These need to be repaired as necessary to prevent leakage.
- STAIR RAILING UPGRADE - Stairs with four or more steps should have a safety
railing. We recommend that an approved handrail be installed.
- STAIR/LANDING MOISTURE MEMBRANE FAILED - The moisture membrane has failed.
Water has penetrated through the membrane. There may be damaged framing below. All
damaged material must be replaced or the damage may spread. Moisture must be prevented
from penetrating the framing or additional damage will occur. Our primary recommendation
is to install a new moisture membrane. This will stop any further leakage and subsequent
damage. It may be possible to seal the surface above, thereby, hopefully stopping
further water penetration. However, there is no guarantee that sealing the surface
will work and this repair will require frequent maintenance.
- STUD - A vertical, framing member in a wall or partition, usually spaced
from twelve to sixteen inches apart.
- SURFACE GRANULATION FAILURE
- An indication of roofing surface wear due to exposure. This wear will continue
and leaks may eventually develop. This condition is one indication that the roof
is nearing the end of its useful life. Until the roof is replaced, it should be
periodically examined by a qualified and licensed roofing contractor for indications
of further wear significant enough to result in moisture penetration and repairs
should be made as necessary.

T

- TEMEPERATURE/PRESSURE VALVE - A safety valve designed to release excess temperature
and pressure. Commonly used in water heaters and steam boilers.
- THERMOSTAT - An automatic heating/cooling control device. Some units are
controlled by clocks to set back the temperature during certain time periods as
a fuel-saving measure.
- TILE ROOF - Fired clay, stone or concrete roofing material. Tile roofs are
highly resistant to wear and have a life expectancy of fifty plus years. However,
problems can develop and these problems need attention in order to prevent leakage.
Walking on a tile roof may result in some tile breakage; therefore, we examine tile
roofs from ground level and other vantage points. We look for cracked and missing
tiles and cracked and deteriorated tile mortar joints. We also examine the visually
accessible connection and penetration flashings for damage and defects. Problems
in these areas create opportunities for leakage and must be corrected to prevent
moisture penetration. The watertightness of a tile roof depends to a large degree
on the condition of the felt underlayment. The only way to completely examine the
underlayment is to remove all of the tile. This, of course, is not practical. We
inspect the felt underlayment by lifting up the tiles at a random number of places.
If the felt is found to be deteriorated, it must be repaired. Repairing the underlayment
requires removing the tile and it may not be possible to reuse the tile. Often times
repairing the underlayment results in replacing all of the tile and flashing around
the connections and penetrations. Problems may be present at areas we were unable
to access. We recommend that tile roofs be periodically examined by a qualified
and licensed roofing contractor. Occasionally tile roofing surfaces are installed
directly over the sheathing without an underlayment. An underlayment provides a
moisture barrier between the tile and the attic. The manufacturer's specifications
may permit this method of installation; however, it is our opinion that without
an underlayment, a tile roof is subject to premature leakage. In such cases, we
recommend that the tile surface and the connections and penetrations be frequently
examined by a qualified and licensed roofing contractor for signs of damage and
leakage and repairs made if necessary.
- TOILET LOOSE - When a toilet is not securely fastened to the floor, the wax
ring seal can deteriorate, causing the toilet to leak. A leaking toilet can damage
the floor and the floor framing. A toilet can leak for some time before the damage
becomes visible. We recommend that the wax ring seal be replaced now and the toilet
be securely fastened before the need for additional costly repairs becomes necessary.
- TON OF REFRIGERATION - A measure of the rate of refrigeration equal to 12,000
BTU per hour.
- TRAP - A fitting to provide a liquid seal that prevents the back passage
of gases, without materially affecting the flow of sewage or water through it.
- TRANSITE VENT ā A pipe composed chiefly of asbestos and portland cement used
to carry products of combustion from gas fired appliances safely to the exterior
of a dwelling. Transite vents are not recognized by present code. They are subject
to failure because of their absorbency and the effect of the products of combustion
on the product binders. The local building department may require replacement of
these vents. Asbestos has been determined by the U.S. Consumer Product Safety Commission
to be a health hazard. There are a number of choices available in dealing with asbestos.
They include leaving it alone, encapsulation and abatement. Removal of this material
is a specialized procedure and should be attempted only by a qualified and licensed
expert. Information regarding identification of asbestos, its hazards and safe removal
may be obtained from the U.S. Consumer Product Safety Commission (800) 638-CPSC,
Environmental Protection Agency and other governmental agencies.
- TRANSITION BOOT
- A rectangular box attached to the end of a duct into which the register is placed.

U

- UNDERLAYMENT - Building material, generally paper or felt, used as a protection
against the passage of air and moisture.
- UNDERSIZED GAS CONNECTOR - We found an undersized gas connector at one or
more of the appliances. The diameter of the gas supply piping should be no smaller
than the inlet connection of the appliance. We recommend that the connector be removed
and an approved connector installed in accordance with standard building practice.
- UNSTEADY DECK OR STAIRWAY - Movement due to a lack of cross bracing. We recommend
that additional structural members be installed as necessary to eliminate this movement.
- UPGRADE DRAINAGE - We found excessive moisture in the foundation area. This
moisture can damage the foundation and framing, plumbing piping and heating ducts.
It is our opinion that there is either insufficient or defective site drainage.
We, therefore, recommend that a qualified and licensed drainage engineer be contacted
to design and install a perimeter drainage system. This drainage system should collect
the surface as well as the subsurface waters approaching the foundation system,
and divert them to some type of central drainage collection or disposal point.
- UPGRADE THE SHOWER WALLS - We found bathroom shower wall material extends
only part way up the receiving walls. This construction detail is conducive to moisture
penetration into and subsequent damage in presently concealed areas behind the shower
walls. We found no outward indications of leakage or damage. However, with access
and an opportunity for examination, reportable conditions may be discovered. If
review of these inaccessible areas is desired, this will be performed upon arrangement
at an additional cost to the interested parties at such time as access can be provided.
Ideally, the shower walls should be upgraded and extended above the shower arm.
- UPGRADING RECOMMENDED
- These are changes that we feel would be beneficial to the functional use of a
system and/or component. They are not required.

V

- VALLEY - A depressed angle formed where two roof planes meet.
- VAPOR BARRIER - A material or paint applied to a wall, floor or ceiling to
prevent the passage of moisture. Plastic vapor barriers are sometimes applied over
the subarea soil. This helps create a dry air space between damp soil and wood framing
and limits the amount of moisture able to rise into the framing, thereby reducing
moisture damage. A plastic vapor barrier also provides a reasonable surface upon
which to crawl in the event of needed access to a moist subarea. Finally, a plastic
vapor barrier tends to keep moist soil from drying out completely and reduces the
subsequent shrinkage and cracking that often occurs. This reduces the settlement
often associated with expansive soil subject to fluctuating moisture content.
- VENT (PLUMBING) - A pipe installed to provide a flow of air to or from a
drainage system and to minimize possibilities of trap siphonage and back pressure.
- VEGETATION ENCROACHMENT - Vines and/or shrubbery that cover the exterior
finished siding, foundation vents, decks, stairways and electrical equipment. This
vegetation can cause damage. We recommend that all shrubbery against sidewalls and
foundation vents be cut back. Tree limbs and branches that have overgrown or surround
the electrical service entrance conductor wires should be removed.
- VOLTAGE
- Electric power. The greater the speed at which electrons travel, the more power
present (240 volts is more powerful than 120 volts).

W

- WARM AIR SYSTEM - A heating system in which air is heated inside a furnace
and distributed throughout the house by means of convection.
- WASTE AIR GAP - A sink device installed between the dishwasher and the drain
line. Its purpose is to prevent the drawing of waste water into the dishwasher.
- WATT - The amount of electricity flowing through a line, measured in terms
of watts. Volts multiplied by amps equals watts.
- WATER HAMMER - A sudden pounding noise in a piping system caused by rapid
pressure changes due to very quick closing of valves or other restrictions. It is
possible to correct this condition by installing an air chamber.
- WATER PRESSURE - 55 pounds per square inch is considered in the mid-range
of normal water pressure. Less than 30 psi is considered in the low-range of normal
water pressure. This usually occurs as a result of mineral deposits building up
inside the domestic water supply piping which restrict the flow of water. The corroded
lines eventually will need to be replaced. Excessive water pressure (above 100 psi)
puts unnecessary strain on the water heater, water lines and fixtures which can
result in leaks. We recommend that a pressure reduction valve be installed in such
instances.
- WET VENT - A vent that also serves as a drain. Most modern plumbing practices
do not permit wet vents. This condition should be corrected.
- WOOD FLOOR INSTALLED OVER AN UNKNOWN SURFACE
- Ground level wooden flooring that has been constructed on wood framing slightly
elevated over an unknown surface below. This type of construction is conducive to
framing damage within the concealed areas. We found no evidence to suggest the presence
of damage. However, with access and an opportunity for examination, reportable conditions
may be discovered. We recommend that portions of the flooring be removed to provide
sufficient access to determine the presence and extent of any damage, and any necessary
corrective measures.

Copyright © 1999 BPG Corporation. All Rights